The facility

Orlando's original telecom hotel

The building was the de facto telecom hotel at the intersection of multiple fiber routes; carriers and providers consolidated into the space over time. That is why it is one of the most connected facilities in central Florida — and it is not something a newer building can replicate.

100 W. Lucerne Circle, Suite 201, Orlando, FL 32801. Carrier-neutral, N+1 across power, cooling and connectivity, operating since 1997.

Schedule a tour See the carrier list

Power

The Priority 1 utility feed is the specification most worth understanding: after a regional outage, the facility is on the same restoration priority as a hospital.

Power infrastructure
Utility feeds Two independent utility feeds. One is part of the Priority 1 hospital utility grid, giving the facility priority restoration after a regional outage.
Generators Three diesel generators in an N+1 farm, with automatic transfer switches to the facility and generator-to-generator ATS.
UPS Redundant (N+1) UPS systems, plus redundant DC power.
Distribution Cabinets wired into an “always on” grid for continuous power.
Standby generator and fuel tank at the facility

Three generators, and the fuel to run them

An N+1 generator farm with automatic transfer switches to the facility and generator-to-generator ATS. On-site diesel storage means the transfer is not the end of the story.

Standby generator and fuel tank at the facility

UPS plant on the data center floor

Redundant N+1 UPS

Conditioned AC power through redundant UPS systems, plus redundant DC power, carrying the load between a utility interruption and the generators coming up.

UPS plant on the data center floor

Cooling and environmental

Cooling, monitoring and detection
Redundancy N+1 across cooling as well as power and connectivity.
Monitoring CRAC units, temperature and humidity monitored continuously alongside power, ATS, batteries and generators.
Detection Fire detection and suppression, smoke and heat monitoring, and water detection.
Liebert air handler control panel showing cooling and humidifying, no alarms present

Monitored continuously, not periodically

Air handling, temperature and humidity are monitored alongside power, ATS, batteries and generators. Alarm state is visible on the floor rather than only in a dashboard.

Liebert air handler control panel showing cooling and humidifying, no alarms present

Hot aisle marking on the raised floor between cabinet rows

Hot and cold aisle discipline

Cabinets are laid out so exhaust air is directed into the hot aisle and cool air is not short-circuited. Aisles are marked on the floor because a containment scheme only works if everyone racking equipment follows it.

Hot aisle marking on the raised floor between cabinet rows

Physical security

Access control and surveillance
Authentication Dual factor — proximity key card and PIN.
Entry Mantrap at the facility entrance.
Cabinets Uniquely keyed locking cabinets.
Surveillance Recorded video with 90-day retention.
Access 24/7/365 unescorted access for authorized personnel only.
Independently examined Physical and environmental controls are in scope of the SOC 2 Type 2 examination (Security and Availability). — 360 Advanced
Proximity card reader with PIN keypad at a facility door

Two factors at every reader

Every door in the facility is proximity card plus PIN. A card on its own opens nothing — which is the difference between a credential being lost and a facility being entered.

Proximity card reader with PIN keypad at a facility door

FM-200 manual discharge and system abort stations beside the cabinet rows

Clean-agent fire suppression

FM-200 suppression with manual discharge and abort stations on the floor, alongside smoke, heat and water detection.

FM-200 manual discharge and system abort stations beside the cabinet rows

Space and service levels

Cabinets, availability and roof access
Cabinet options One-third rack (12RU) or full rack (42RU) locking cabinets.
Availability SLA 99.99% of the time in a given month for critical power and HVAC, excluding scheduled maintenance and upgrades. — MSA Exhibit C
Roof rights Exclusive roof rights — antennae, dishes and similar devices.
Cold aisle between locking cabinet rows

One-third rack to full cabinet

Locking cabinets in 12RU and 42RU configurations on a raised floor, with perforated tiles delivering cool air where the equipment draws it.

Cold aisle between locking cabinet rows

Private caged suite within the data center floor

Private cage where a cabinet is not enough

Caged space for deployments that need their own physical boundary inside the hall — compliance-driven separation, or simply more equipment than a row of cabinets holds.

Private caged suite within the data center floor

Availability figures are service level commitments under Exhibit C of the Master Services Agreement, which contains the governing definitions, exclusions and remedies.